1、检查备服务器硬件状况,在PC上打开浏览器输入BMC地址,输入用户名密码进入管理界面。查看服务器日志,服务器并没有产生任何告警信息。
2、客户授权登录操作系统,并提供用户名和密码,通过终端登录操作系统。使用命令“ifconfig”查看网络接口信息,发现只有eth0和eth1。[root@localhost~]#ifconfigeth0Linkencap:HWaddr00:0C:29:3D:80:addr:172.16.1.20Bcast:172.16.255.255Mask:6addr:fe80::20c:29ff:fe3d:808b/64Scope:LinkUPBROADCASTRUNNINGMULTICASTMTU:Metric:1RXpackets:142errors:0dropped:0overruns:0frame:0TXpackets:125errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:RXbytes:(30.5KiB)TXbytes:(21.0KiB)eth1Linkencap:HWaddr00:0C:29:3D:80:addr:192.16.1.20Bcast:192.16.1.255Mask:6addr:fe80::20c:29ff:fe3d:/64Scope:LinkUPBROADCASTRUNNINGMULTICASTMTU:Metric:1RXpackets:133errors:0dropped:0overruns:0frame:0TXpackets:65errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:RXbytes:(25.4KiB)TXbytes:(11.6KiB)loLinkencap:addr:127.0.0.1Mask:6addr:::1/128Scope:HostUPLOOPBACKRUNNINGMTU:Metric:1RXpackets:14errors:0dropped:0overruns:0frame:0TXpackets:14errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:0RXbytes:(1.1KiB)TXbytes:(1.1KiB)
3、进入"/etc/work-scripts"目录下查看配置文件。[root@work-scripts]#lsifcfg-*Ifcfg-bond0ifcfg-eth0ifcfg-eth1ifcfg-eth2ifcfg-eth3ifcfg-lo可以看出系统已经识别了eth2和eth3网卡。查看配置文件发现bond0配置文件有如下错误:[root@work-scripts]#catifcfg-bond0DEVICE=bond0BOOTPROTO=staticIPADDR=192.168.1.20NETMASK=23GATEWAY=192.168.1.254ONBOOT=yes修改配置文件:[root@work-scripts]#catifcfg-bond0DEVICE=bond0BOOTPROTO=staticIPADDR=192.168.1.20NETMASK=255.255.255.0GATEWAY=192.168.1.254ONBOOT=yes重启网络服务后,eth2和eth3指示灯正常。根因
1、扩展槽外接网卡松动。
2、网卡类型不匹配。
3、外接网卡硬件故障。
4、网络接口配置文件错误。解决方案
1、检查备服务器硬件状况,在PC上打开浏览器输入BMC地址,输入用户名密码进入管理界面。查看服务器日志,服务器并没有产生任何告警信息。
2、客户授权登录操作系统,并提供用户名和密码,通过终端登录操作系统。使用命令“ifconfig”查看网络接口信息,发现只有eth0和eth1。[root@localhost~]#ifconfigeth0Linkencap:HWaddr00:0C:29:3D:80:addr:172.16.1.20Bcast:172.16.255.255Mask:6addr:fe80::20c:29ff:fe3d:808b/64Scope:LinkUPBROADCASTRUNNINGMULTICASTMTU:Metric:1RXpackets:142errors:0dropped:0overruns:0frame:0TXpackets:125errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:RXbytes:(30.5KiB)TXbytes:(21.0KiB)eth1Linkencap:HWaddr00:0C:29:3D:80:addr:192.16.1.20Bcast:192.16.1.255Mask:6addr:fe80::20c:29ff:fe3d:/64Scope:LinkUPBROADCASTRUNNINGMULTICASTMTU:Metric:1RXpackets:133errors:0dropped:0overruns:0frame:0TXpackets:65errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:RXbytes:(25.4KiB)TXbytes:(11.6KiB)loLinkencap:addr:127.0.0.1Mask:6addr:::1/128Scope:HostUPLOOPBACKRUNNINGMTU:Metric:1RXpackets:14errors:0dropped:0overruns:0frame:0TXpackets:14errors:0dropped:0overruns:0carrier:0collisions:0txqueuelen:0RXbytes:(1.1KiB)TXbytes:(1.1KiB)
3、进入"/etc/work-scripts"目录下查看配置文件。[root@work-scripts]#lsifcfg-*Ifcfg-bond0ifcfg-eth0ifcfg-eth1ifcfg-eth2ifcfg-eth3ifcfg-lo可以看出系统已经识别了eth2和eth3网卡。查看配置文件发现bond0配置文件有如下错误:[root@work-scripts]#catifcfg-bond0DEVICE=bond0BOOTPROTO=staticIPADDR=192.168.1.20NETMASK=23GATEWAY=192.168.1.254ONBOOT=yes修改配置文件:[root@work-scripts]#catifcfg-bond0DEVICE=bond0BOOTPROTO=staticIPADDR=192.168.1.20NETMASK=255.255.255.0GATEWAY=192.168.1.254ONBOOT=yes重启网络服务后,eth2和eth3指示灯正常。建议与总结
1、遇到问题善于发现问题的原因,通过问题原因一步一步排查故障,这样处理故障的效率才能提高。
2、工作中也遇到过其它序列服务器某网卡指示灯不亮,下架检查,使用ifconfigethXup后,网卡指示灯正常,上架重启后指示灯又熄灭,原因是配置文件“ONBOOT”设置成“no”,将“no”改为“yes”后恢复正常。
3、网卡灯不亮并不一定是硬件故障,大多时候是网络接口配置错误,发现类似问题应该先检查配置脚本。